Autores
O Ferreira, G Bogaert, A Bonnemaison, G Drevillon, P Fleury, B Giebels, P Prat, D Bédérède, P Bourgeois, B Cordier, FX Gentit, B Horeau, Y Piret
Fecha de publicación
2004/9/11
Revista
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volumen
530
Número
3
Páginas
323-329
Editor
North-Holland
Descripción
This paper describes the results of vibration tests using the Validation Module of the GLAST Gamma Large Area Telescope calorimeter structure. The composite structure has been tested with different vibration spectra expected during the launch environment of GLAST. No degradation of the mechanical assembly was observed, and deformations and displacements stayed within stay-clear limits.