| A PLS regression model using NIR spectroscopy for on-line monitoring of the biodiesel production reaction MHM Killner, JJR Rohwedder, C Pasquini Fuel 90 (11), 3268-3273, 2011 | 67 | 2011 |
| Compact NMR spectroscopy for real-time monitoring of a biodiesel production MHM Killner, YG Linck, E Danieli, JJR Rohwedder, B Blümich Fuel 139, 240-247, 2015 | 52 | 2015 |
| Mobile low-field 1 H NMR spectroscopy desktop analysis of biodiesel production YG Linck, MHM Killner, E Danieli, B Blümich Applied Magnetic Resonance 44 (1), 41-53, 2013 | 33 | 2013 |
| Mobile compact 1H NMR spectrometer promises fast quality control of diesel fuel MHM Killner, E Danieli, F Casanova, JJR Rohwedder, B Blümich Fuel 203, 171-178, 2017 | 21 | 2017 |
| Kinetic study of the transesterification reaction by artificial neural networks and parametric particle swarm optimization D Galvan, H Cremasco, ACG Mantovani, E Bona, M Killner, D Borsato Fuel 267, 117221, 2020 | 15 | 2020 |
| Increasing the detection distance of remote NMR using wireless inductive coupling coil MHM Killner, G Tosin, AS Carvalho, DF Bernardes, LA Colnago Scientific reports 7 (1), 1-6, 2017 | 5 | 2017 |
| Online monitoring of transesterification reaction by medium-resolution benchtop 1H NMR and NIR spectroscopy D Galvan, LM de Aguiar, JJR Rohwedder, D Borsato, MHM Killner Fuel Processing Technology 208, 106511, 2020 | 4 | 2020 |
| Mathematical Modeling of the Transesterification Reaction by Finite Elements: Optimization of Kinetic Parameters Using the Simplex Sequential Method D Galvan, LT Chendynski, ACG Mantovani, MB Quadri, M Killner, ... Journal of the Brazilian Chemical Society 31, 313-319, 2020 | 4 | 2020 |
| Calibration transfer of partial least squares regression models between desktop nuclear magnetic resonance spectrometers D Galvan, E Bona, D Borsato, E Danieli, MH Montazzolli Killner Analytical Chemistry 92 (19), 12809-12816, 2020 | 3 | 2020 |
| Application of low-field and medium-resolution 1H NMR spectroscopy combined with chemometric methods for automotive gasoline quality control LM de Aguiar, E Bona, LA Colnago, JJR Rohwedder, MHM Killner Fuel 282, 118684, 2020 | 1 | 2020 |
| Emprego da espectroscopia NIR e de RMN 1H de baixo campo no monitoramento da reação de transesterificação para a produção de biodiesel: determinação de parâmetros de qualidade … MHM Killner [sn], 2013 | 1 | 2013 |
| Desenvolvimento de um sistema voltametrico microfluidico MHM Killner [sn], 2007 | 1 | 2007 |
| Compact low-field NMR spectroscopy and chemometrics applied to the analysis of edible oils D Galvan, AAC Tanamati, F Casanova, E Danieli, E Bona, MHM Killner Food Chemistry 365, 130476, 2021 | | 2021 |
| Calibration transfer between low-field NMR instruments D Galvan, E Danieli, D Borsato, M Killner ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY 258, 2019 | | 2019 |
| Mobile compact 1H NMR spectroscopy for on-line monitoring of the biodiesel production reaction D Galvan, LM de Aguiar, D Borsato, J Rohwedder, M Killner ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY 255, 2018 | | 2018 |
| Desenvolvimento de métodos simples e rápidos para o controle de qualidade de blendas de combustíveis fósseis e biocombustíveis empregando RMN de baixo campo. MHMC KILLNER, JJR AS ROHWEDDER, LA COLNAGO Embrapa Instrumentação-Artigo em anais de congresso (ALICE), 2014 | | 2014 |